Model EF-1218 (PN 40)

Click here to download the data-sheet

Model-EF-1418-PN-100

Item number: 101218STA330
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 3″ Class 300 RF

Nom. press. stage: PN 40
Medium: Steam, compressed air, pressurised gases and cooling agents on request
Function: Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations.
Material:
  • Several types of steel
  • ASTM
Characteristics: Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device.
Installation: Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation

Item number: 101218STA331
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 3 1/2″ Class 300 RF

Nom. press. stage: PN 40
Medium: Steam, compressed air, pressurised gases and cooling agents on request
Function: Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations.
Material:
  • Several types of steel
  • ASTM
Characteristics: Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device.
Installation: Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation

Item number: 101218STA340
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 4″ Class 300 RF

Nom. press. stage: PN 40
Medium: Steam, compressed air, pressurised gases and cooling agents on request
Function: Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations.
Material:
  • Several types of steel
  • ASTM
Characteristics: Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device.
Installation: Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation

Item number: 101218ST1080
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 DN 80

Connection: DN 80
Nom. press. stage: PN 40
Medium: Steam, compressed air, pressurised gases and cooling agents on request
Function: Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations.
Material:
  • Several types of steel
  • ASTM
Characteristics: Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device.
Installation: Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation

Item number: 101218ST1100
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 DN 100

Connection: DN 100
Nom. press. stage: PN 40
Medium: Steam, compressed air, pressurised gases and cooling agents on request
Function: Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations.
Material:
  • Several types of steel
  • ASTM
Characteristics: Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device.
Installation: Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation