Model EF-1218 (PN 40)
Click here to download the data-sheet

Item number: 101218STA330
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 3″ Class 300 RF
| Nom. press. stage: | PN 40 |
| Medium: | Steam, compressed air, pressurised gases and cooling agents on request |
| Function: | Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations. |
| Material: |
|
| Characteristics: | Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device. |
| Installation: | Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation |
Item number: 101218STA331
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 3 1/2″ Class 300 RF
| Nom. press. stage: | PN 40 |
| Medium: | Steam, compressed air, pressurised gases and cooling agents on request |
| Function: | Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations. |
| Material: |
|
| Characteristics: | Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device. |
| Installation: | Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation |
Item number: 101218STA340
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 4″ Class 300 RF
| Nom. press. stage: | PN 40 |
| Medium: | Steam, compressed air, pressurised gases and cooling agents on request |
| Function: | Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations. |
| Material: |
|
| Characteristics: | Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device. |
| Installation: | Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation |
Item number: 101218ST1080
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 DN 80
| Connection: | DN 80 |
| Nom. press. stage: | PN 40 |
| Medium: | Steam, compressed air, pressurised gases and cooling agents on request |
| Function: | Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations. |
| Material: |
|
| Characteristics: | Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device. |
| Installation: | Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation |
Item number: 101218ST1100
RIFOmat Float – Controlled Trap PN 40
Model EF-1218 DN 100
| Connection: | DN 100 |
| Nom. press. stage: | PN 40 |
| Medium: | Steam, compressed air, pressurised gases and cooling agents on request |
| Function: | Increasing level opens and decreasing level closes the outlet without delay, independent of pressure and temperature fluctuations. |
| Material: |
|
| Characteristics: | Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device. |
| Installation: | Angular type: condensate inlet at the top, lateral outlet or, with threaded ports G 1/2″, horizontal installation |