RIFOmax
Model Minox – Light 15001 (PN 16)
Item number: 115001AL2012
RIFOmat Automatic Water Extractor PN 16
Model Minox – Light 15001
| Connection: | G 1/2″ | ![]() |
| Nom. press. stage: | PN 16 | |
| Medium: | Compressed air, pressurised gases | |
| Function: | Increasing level opens and decreasing level closes the outlet without delay, independent of pressure fluctuations. | |
| Material: |
|
|
| Characteristics: | Only one movable point since the rotary-slide-valve is both a swivel joint and shut-off device. | |
| Installation: | Angular type: condensate inlet at top, outlet on the side |
Model Pressoquick – 14201-N (PN 40)
Item number: 114201N12012
RIFOmat Automatic Water Extractor PN 40
Model Pressoquick-14201 – N G 1/2″ (BSP) / 1/8″ NPT
| Nom. press. stage: | PN 40 |
| Medium: | Water / condensat |
| Function: | The valve closes during system start-up and rise of operating pressure to more than 0,2 – 0,3 bar. After a drop of operating pressure to 0,2 – 0,3 bar the valve opens and start-up fluid and residual fluid drains. |
| Characteristics: | Automatic drainage of water and condensate during start-up and system shutdown. Due to residual drainage there are no freezing of condensate discharge units, compressed air systems and pipelines, such as fire-extinguisher lines, thus increasing safety. |
| Installation: | Horizontal or vertical for drainage at lowest system point. See figures 1 and 2. |
![]() | |